subject
Engineering, 26.11.2019 06:31 stuckonquestions

A4-pole, 60hz, y-connected, 3-phase generator has a regulated line voltage
of vab = 450∠30° vrms, a synchronous reactance of 0.05-ω, a stator resistance of 0.003ω,
and lsf = 0.018 h. the balanced 3-phase load draws 3 mw at a lagging 0.75 power
factor.
a. compute the 3-phase complex power of the load (magnitude and angle).
s3p =
b. compute the generator phase current (magnitude and angle; hint: the angle of the
current should be negative for the load to have a lagging power factor).
ias =
c. find the required excitation voltage.
ea =
d. calculate the required field current.
if =
e. state the required speed of the prime mover (rpm) nm =

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, cowgyrlup124
Explain the difference laminar and turbulent flow. explain it with the shear stress and the velocity profiles.
Answers: 1
image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
image
Engineering, 04.07.2019 18:10, soreese02
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
image
Engineering, 04.07.2019 18:10, wyattlb97
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
You know the right answer?
A4-pole, 60hz, y-connected, 3-phase generator has a regulated line voltage
of vab = 450∠30° vr...

Questions in other subjects:

Konu
Mathematics, 13.03.2021 09:30
Konu
Biology, 13.03.2021 09:30