subject
Engineering, 16.11.2019 06:31 sethhdoty

A20,000-liter storage tank was taken out of service to repair and reattach a feed line damaged in a collision with a tanker. the tank was drained and then opened several days later for a welder to enter and perform the required work. no one realized, however, that 5 liters of liquid nonane (c9h20) remained in a collection sump at the bottom of the tank after the draining had been completed.

(a)

nonane has a lower explosive limit of 0.80 mole% and an upper explosive limit of 2.9 mole%8 (i. e., nonane-air mixtures at 1 atm can explode when exposed to a spark or flame if the nonane mole fraction is between the two given values). assume any liquid nonane that evaporates spreads uniformly throughout the tank. is it possible for the average gas-phase composition in the tank to be within the explosive limits at any time? even when the average composition falls outside those limits, why is an explosion still a possibility?

(hint: think about that assumption.)

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, brooklyn674
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
image
Engineering, 04.07.2019 08:10, doggo242
Which of the following is an easy way to remember the modified “x” tire rotation? a. nondrive wheels straight, cross the drive wheels b. drive wheels straight, cross the nondrive wheels c. drive wheels crossed, nondrive wheels straight d. drive wheels crossed, nondrive wheels crossed
Answers: 1
image
Engineering, 04.07.2019 18:10, leomessifanboy678
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
A20,000-liter storage tank was taken out of service to repair and reattach a feed line damaged in a...

Questions in other subjects:

Konu
History, 21.12.2020 15:30
Konu
Social Studies, 21.12.2020 15:30
Konu
Social Studies, 21.12.2020 15:30
Konu
Mathematics, 21.12.2020 15:30
Konu
English, 21.12.2020 15:30
Konu
Mathematics, 21.12.2020 15:30