subject
Engineering, 13.11.2019 01:31 Ivy2k

The chief architect in charge of designing your company’s new processor has drafted an isa that includes many operations: add, subtract, xor, xnor, and, nand, or, nor, and not. the total number of opcodes (including operations, data movement, and control flow) is 19. the chief architect suggests having 15 registers in the register file. instructions that require three register operands then need ceiling [log2 (19 × 15 × 15 × 15)] = 16 bits. in a few sentences, explain to the chief architect why eliminating a few of the opcodes and allowing 16 registers is a better choice in terms of the microarchitecture. for credit, your response must also allow for 16-bit instructions. be specific about which opcodes should be eliminated.

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, settasav9641
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
image
Engineering, 04.07.2019 18:10, lerasteidl
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
image
Engineering, 04.07.2019 18:20, cxttiemsp021
Atank with constant volume contains 2.27 kg of a mixture of water phases (liquid-vapor). in the initial state the temperature and the quality are 127 °c and 0.6, respectively. the mixture is heated until the temperature of 160 oc is reached. illustrate the process in a t-v diagram. then, determine (1) the mass of the vapor in kg at the initial state, (2) the final pressure in kpa.
Answers: 3
You know the right answer?
The chief architect in charge of designing your company’s new processor has drafted an isa that incl...

Questions in other subjects:

Konu
Mathematics, 10.10.2021 18:20
Konu
Mathematics, 10.10.2021 18:20
Konu
Mathematics, 10.10.2021 18:20
Konu
Mathematics, 10.10.2021 18:20
Konu
Mathematics, 10.10.2021 18:20