Engineering, 11.11.2019 19:31 isabel81ie
Consider a combined gas-steam power cycle. the topping cylce is a simple brayton cylce that has a pressure ratio of 7. air enters the compressor at 15 degrees c at a rate of 10 kg/s and the gas turbine at 950 degrees c. the bottoming cylce is reheat rankine cylce between the pressure limits of 6 mpa and 10kpa. steam is heated in a heat exchanger at a rate of 1.15 kg/s by the exhaust gases leaving the gas turbine and the exhaust gases leave the heat exchanger at 200 degrees c. steam leaves the high-pressure turbine at 1.0 mpa and is reheated to 400 degrees c in the heat exchanger before it expands in the low-pressure turbine. assuming 80 percent isentropic efficiency for all pumps and turbines, deteremine
(a) the moisture content at the exit of low-pressure turbine,
(b) the steam temperature at the inlet of the high-pressure turbine,
(c) the net power output and the thermal efficiency of the combined plant.
![ansver](/tpl/images/cats/User.png)
Answers: 2
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, lowkeyqueenk
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, siri5645
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, oliviasoreo92
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, DroctorWellsfan
Inspection for bearing condition will include: (clo4) a)-color b)-smell c)-size d)-none of the above
Answers: 1
You know the right answer?
Consider a combined gas-steam power cycle. the topping cylce is a simple brayton cylce that has a pr...
Questions in other subjects:
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 24.09.2020 15:01
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 24.09.2020 15:01
![Konu](/tpl/images/cats/ekonomika.png)
Business, 24.09.2020 15:01
![Konu](/tpl/images/cats/biologiya.png)
![Konu](/tpl/images/cats/himiya.png)
Chemistry, 24.09.2020 15:01
![Konu](/tpl/images/cats/mat.png)
Mathematics, 24.09.2020 15:01