subject
Engineering, 31.10.2019 02:31 shavonfriend27

1.a room is to be maintained at 73 °f. the outside temperature is 92 °f. there are 11 people in the room, each generating 320 btu/hr of heat. there are 1800 watts of lighting in the room, of which 20 % goes to heat. the room has one outside wall (with no windows), which has r-8 insulation and an area of 240 ft2. the room is being cooled by air conditioners with an eer rating of 9. assume the eer rating stays constant no matter what the outdoor temperature. a.what is the heat gain in the room due to people? (include units with answer)hint #1: same units as heat generated, given in problem. b.what is the heat gain in the room due to the lighting? (include units with answer)c. what is the heat gain in the room due to heat conduction through the outside wall? (include units with answer)hint #1: r-8 means the thermal resistance is 8 (ft2-hr-°f)/btud. how much electrical power is required to run the air conditioner? (include units with answer)hint #1: eer has units of (btu/hr)/watt. use these mixed units to your advantage! e. if the air conditioner were running at the maximum possible efficiency, how much electrical power is required to run the air conditioner? (include units with answer)

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 03:10, lauriepdx17
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
image
Engineering, 04.07.2019 18:20, rocio5649
Amixture of slurry and mud is to be pumped through a horizontal pipe of diameter 500 mm. the fluid behaves as a bingham plastic with a yield stress of 30 pa and viscosity 0.04 pa. s. describe the effects of the shear stress through a transverse section of the pipe by plotting the variation in shear stress and velocity profile: (i) just before the slurry starts to move (ii) as the slurry flows when the pressure gradient is double that in part (i)
Answers: 3
image
Engineering, 04.07.2019 19:20, diawia
Air at a pressure of 1atm and a temperature of 40 c is in parallel flow over the top surface of a flat plate that is heated to a uniform temperature of 120 c. the plate has a length of 0.40m (in the flow direction) and a width of 0.15m. the reynolds number based on the plate length is 50, 000. what is the rate of heat transfer from the plate to the air? if the free stream velocity of the air is doubled and the pressure is increased to 10 atm what is the rate of heat transfer?
Answers: 2
image
Engineering, 06.07.2019 02:30, onlymyworld27
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
You know the right answer?
1.a room is to be maintained at 73 °f. the outside temperature is 92 °f. there are 11 people in the...

Questions in other subjects: