subject
Engineering, 10.10.2019 05:00 charityclark3935

Parallel flow of air over a flat plate of length 3m is disrupted by an array of stationary rods placed in the flow path over the plate. an empirical correlation for the local heat transfer coefficient is obtained for a velocity, v and ts> [infinity]t: hx=0.7+13.6x-3.4x2, where hx has units of w/(m2*k) and x is in meters. evaluate the average heat transfer coefficient for the entire plate and the ratio llh/h at the trailing edge. also plot the heat transfer coefficient as a function of x (from x=0 to x=3m). how does this plot compare to flow over a flat plate without any stationary rods?

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 19:10, shunna33
Plan an experiment to measure the surface tension of a liquid similar to water. if necessary, review the ncfmf video surface tension for ideas. which method would be most suitable for use in an undergraduate laboratory? what experimental precision could be expected?
Answers: 2
image
Engineering, 04.07.2019 19:10, nbug2121
Arigid tank contains 10 kg of air at 137 kpa (abs) and 21°c. more air is added to the tank until the pressure and temperature rise to 242 kpa (abs) and 32°c, respectively. determine the amount of air added to the tank. [r-0.287 kj/kg k]
Answers: 3
image
Engineering, 04.07.2019 19:20, Katmcfee7681
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
image
Engineering, 04.07.2019 19:20, carterdaw
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
You know the right answer?
Parallel flow of air over a flat plate of length 3m is disrupted by an array of stationary rods plac...

Questions in other subjects:

Konu
Mathematics, 23.10.2020 20:50
Konu
Mathematics, 23.10.2020 21:00