![subject](/tpl/images/cats/User.png)
Engineering, 04.10.2019 22:20 PushyGorilla
The length of a 60 w , 240 ω light bulb filament is 60 cm . part a if the potential difference across the filament is 120 v , what is the strength of the electric field inside the filament? express your answer in volts per meter. e e = nothing v/m submitrequest answer part b suppose the length of the bulb's filament were doubled without changing its diameter or the potential difference across it. what would the electric field strength be in this case? express your answer in volts per meter. e e = nothing v/m submitrequest answer part c remembering that the current in the filament is proportional to the electric field, what is the current in the filament following the doubling of its length? express your answer in amperes. i i = nothing a submitrequest answer part d what is the resistance of the filament following the doubling of its length? express your answer in ohms. r r = nothing ω submitrequest answer provide feedback next
![ansver](/tpl/images/cats/User.png)
Answers: 3
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, heidiburgos1own6c0
Fluids at rest possess no flow energy. a)- true b)- false
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, Destinationz
Asteam is contained in a rigid tank with a volume of 1 m3. initially, the pressure and temperature are 7 bar and 500 oc, respectively. the temperature drops due to cooling process. determine: (1) the temperature at which condensation begins in °c, (2) the fraction of the total mass that has condensed when the pressure decreased to 0.5 bar. (3) the volume in m3 occupied by saturated liquid at the final state?
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, Mimidj9279
The sum of the normal stresses does not change as the stress state rotates through an angle. a)-trune b)- false
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, nbunny7208
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces. a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
You know the right answer?
The length of a 60 w , 240 ω light bulb filament is 60 cm . part a if the potential difference acros...
Questions in other subjects:
![Konu](/tpl/images/cats/istoriya.png)
History, 25.09.2019 09:30
![Konu](/tpl/images/cats/mat.png)
Mathematics, 25.09.2019 09:30
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/obshestvoznanie.png)
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/istoriya.png)
![Konu](/tpl/images/cats/es.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 25.09.2019 09:30
![Konu](/tpl/images/cats/en.png)
English, 25.09.2019 09:30