As a manufacturing automation engineer, you are asked to design a control system to automate a bottle-filler machine for bottled water. empty bottles are moved into position beneath the filler nozzle one at time by a conveyor moved by a stepping motor. once a bottle is in position underneath the nozzle, the control system actuates a valve (using an actuator) allowing the water to flow into the bottle. a sensor measures the flow rate and sends it to the control system. the control system determines when to close the valve (using an actuator) to achieve the desired volume of water in the bottle based on the flow rate. the valve is closed via a signal from the control system and the stepping motor advances the next bottle. using the list of sensors and actuators given in the course lectures, design and describe what are the appropriate sensors and actuator to be used to automate the water-filler machine for bottled water. include in your description of the control system, the type of input/output signals (such as binary, analog, and how the system is to utilize the input/output data.

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 16:10, TheOriginalMeyah
An electrical motor raises a 50kg load at a construct velencity .calculate the power of the motor, if it takes 40sec to raise the load through a height of 24m(take g =9.8n/g)
Answers: 2
image
Engineering, 04.07.2019 18:10, ayoismeisjjjjuan
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
image
Engineering, 04.07.2019 18:20, 3076850
Prove the equivalence between the two statements of the 2nd law of thermodynamics (i. e., a violation of one statement leads to the violatio the other statement)
Answers: 2
You know the right answer?
As a manufacturing automation engineer, you are asked to design a control system to automate a bottl...

Questions in other subjects:

Konu
Mathematics, 04.04.2020 09:53