Oxygen is contained in a piston-cylinder system initially at a temperature of 40 °c and a pressure of 150 kpa. the piston is 1 m in diameter and initially 20 cm above the base of the cylinder. heat is added at constant pressure until the piston has moved 30 cm. a)-what is the mass of gas contained in the piston, in kg? b)-what is the final temperature of the system, in k? c)-using the table of properties of oxygen as an ideal gas, calculate the heat added to the system per unit mass, in kj/kg. d)-repeat this calculation assuming that the specific heat as a function of temperature is linear over this range of temperatures (i. e., assuming that the change in temperature is "small"). e)-repeat this calculation without this assumption (i. e., direct integration of empirical relation) f)- discuss the variations in your results across the methods (note: all methods will give close to the same answer, if calculated correctly). g)-using any of the methods that you conclude to be accurate, calculate the change in the specific internal energy of the system, in kj/kg.

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 23:20, abbz13
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, Talos02
Burgers vector is generally parallel to the dislocation line. a)-true b)-false
Answers: 2
image
Engineering, 04.07.2019 18:10, wyattlb97
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
You know the right answer?
Oxygen is contained in a piston-cylinder system initially at a temperature of 40 °c and a pressure o...