Suppose you run a TLC and observe an Rf value consistent with the formation of the desired product. Next, you run a MP analysis and notice that a MP range is too large. Which of the following techniques would you implement? a. use a smaller amount of product for MP analysis
b. use a larger amount of product for MP analysis
c. rerun the TLC and change the mobile phase used
d. recrystallize the product

ansver
Answers: 2

Other questions on the subject: Chemistry

image
Chemistry, 21.06.2019 19:00, RedDemon59
Apeak with a retention time of 407 s has a width at half-height (w1/2) of 7.6 s. a neighboring peak is eluted 17 s later with a w1/2 of 9.4 s. a compound that is known not to be retained was eluted in 2.5 s. the peaks are not baseline resolved. how many theoretical plates would be needed to achieve a resolution of 1.5?